AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-123 555-233-123
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and
translations with information in the software.
Table 10-41. Test #36 Station Status and Translation Audits and Updates
Error
Code
Tes t
Result Description/Recommendation
ABORT Necessary system resources could not be allocated to run
this test.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.
1004 ABORT A valid call seized the port during the test and aborted the
test.
1. Use the display port UUCSSpp command to determine
the station extension.
2. Use the status station extension command to
determine the service state of the port.
3. If the port is in use, wait until the port is idle before
testing. Retry the command at 1-minute intervals no more
than 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test
is not applicable for this type of analog port. This error can be
ignored.
1006 ABORT The port is out-of-service. The busy station extension
command has been given to this port, or it has been taken
out-of-service by the failure of the NPE Crosstalk Test.
1. Look for error type 18 (port busied out) for this port. If this
error is present, release the port (release station
extension), and run the test again.
2. Check for error type 1537 (NPE Crosstalk Test failed) for
this port. If this error is present, investigate the errors
associated with the NPE Crosstalk Test (#6).
3. Make sure that the terminal is connected and in service,
and then retest.
2000 ABORT Response to the test request was not received within the
allowable time period.
Continued on next page