AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-125 555-233-123
Station Present Test (also called Ringing
Application Test) (#48)
This test applies momentary ringing voltage to the terminal equipment and
monitors resulting current flow to determine whether terminal equipment is
connected to the port. This test may cause some terminal equipment to ring briefly
during daily maintenance. If this ringing disturbs the customer or the terminal
equipment, you can disable it via the Tests field on the change station
extension form. However, on some software releases, Tests #6, 7, 161, and 35
also are disabled.
8 FAIL The ringer update failed. There may be an internal software
error.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to fail, escalate the problem.
PASS The software and the port processor have the same status.
Investigate user-reported troubles on this port by running
other port tests, by examining station wiring, or by inspecting
the station.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to make sure that the board translations are
correct. Use the list configuration command, and
resolve any problems.
2. If the board is correctly inserted, issue the busy board
UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This
re-establishes the link between the internal ID and the
port.
6. If this is not the case, check to make sure that a valid
board is inserted.
Table 10-41. Test #36 Station Status and Translation Audits and Updates
— Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page