Maintenance Object Repair Procedures
555-233-123
10-164 Issue 4 May 2002
2. Performing a test board long when the circuit pack is in this state
yields the following abort codes:
■ Ports 1 and 9 abort Test #206 with code 1024
■ Ports 1 and 9 abort Test #205 with code 2000
■ Board level Tests #209 and #210 abort with code 1024
3. The save/restore announcements command times out with:
Error encountered, can’t complete request
The Announcement circuit pack lock-up can be cleared remotely by
performing a soft reset to the circuit pack:
■ busyout board PCSS (this command drops all calls in progress on
the Announcement circuit pack)
■ reset circuit pack using the reset board PCSS command
■ release circuit pack using the release board PCSS command