EasyManua.ls Logo

Avaya Definity SI - Page 950

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedures
555-233-123
10-164 Issue 4 May 2002
2. Performing a test board long when the circuit pack is in this state
yields the following abort codes:
Ports 1 and 9 abort Test #206 with code 1024
Ports 1 and 9 abort Test #205 with code 2000
Board level Tests #209 and #210 abort with code 1024
3. The save/restore announcements command times out with:
Error encountered, cant complete request
The Announcement circuit pack lock-up can be cleared remotely by
performing a soft reset to the circuit pack:
busyout board PCSS (this command drops all calls in progress on
the Announcement circuit pack)
reset circuit pack using the reset board PCSS command
release circuit pack using the release board PCSS command

Table of Contents