EasyManua.ls Logo

Avaya Definity SI - Page 955

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ANNOUNCE (Announce)
Issue 4 May 2002
10-169 555-233-123
32006 Announcement Data Module not available.
1. Use the status command to check the status of the Announcement
Data Module.
32007 Announcement Data Module out of service.
1. Use the status command to check the status of the Announcement
Data Module.
32008 Announcement data is being saved or loaded.
1. Retry the command at two minute intervals a maximum of three times.
2. If the save/restore announcements command fails, escalate the
problem.
32009 Required DATA-CHL is not administered or out of service. (A DATA-CHL is
required to save or restore announcements.)
1. Add a DATA-CHL if none is administered.
2. If a DATA-CHL is administered, use the status command to check the
status of all DATA-CHLs. At least one DATA-CHL should be in the
in-service/idle state.
32010
32013
DATA-CHL is not administered, or it is unavailable. (A DATA-CHL is
required to save or restore announcements.)
1. Add a DATA-CHL if none is administered.
2. If a DATA-CHL is administered, use the status command to check the
status of all DATA-CHLs. At least one DATA-CHL should be in the
in-service/idle state.
32012 Required Announcement Data Module is not administered.
1. Add an Announcement Data Module and repeat the command.
32014 Command timed out on the standby processor [286 systems]. This could
present problems.
1. Check the error and alarm logs for errors and alarms that are logged
against the STBY-SPE (Standby SPE) [286 systems].
Table 10-55. Aux Data Error Codes and Recommended Repair Procedures
Continued
Aux
Data Description/Recommendation
Continued on next page