Maintenance Object Repair Procedures
555-233-123
10-170 Issue 4 May 2002
32015 Time of day not set.
1. Set the time of day, and reenter the save/restore announcements
command.
32016 Internal System errors.
Check for any other ANNOUNCE errors and take corrective action.If there
are no other announcements errors, do the following:
1. Retry the command at two minute intervals a maximum of three times.
2. If the save/restore announcements command fails, escalate the
problem.
Table 10-55. Aux Data Error Codes and Recommended Repair Procedures
— Continued
Aux
Data Description/Recommendation
Continued on next page