Table 10-60. TEST #618 BRI Port Local LAN Looparound
Error
Code
Te s t
Result Description/Recommendation
1015 ABORT The port is not in the out-of-service state.
1. Display the Port Status form using the status bri-port
PCSSpp command to determine which stations or
adjuncts are on this port.
2. Use the extension shown on this form in the status
station command to determine if the station or adjunct is
in use.
3. If the port is in use, wait until it is idle, and use the busyout
port PCSSpp command to place it in the out-of-service
state and repeat this test.
!
WARNING:
Since the “busyout” command is destructive, using this
command prior to the port being idle causes all
transactions associated with the ASAI on the port to be
torn down. Note that third party calls established by an
ASAI adjunct remain connected even though the port is
taken out-of-service.
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command and review the results of the BRI Port
Local LAN Looparound Test to verify the repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Issue the test port long PCSSpp command and review
the results of the BRI Port Local LAN Looparound Test to
verify the repair.
1144 ABORT The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. Issue the test port long PCSSpp command and review
the results of the BRI Port Local LAN Looparound Test to
verify the repair.
2012 ABORT Internal system error
Continued on next page