ASAI-PT
Issue 4 May 2002
10-191 555-233-123
Table 10-63. TEST #625 Receive FIFO Error Counter Test
Error
Code
Te s t
Result Description/Recommendation
2000 ABORT Response was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset
the circuit pack via the busyout board PCSS and reset
board PCSS commands.
2. If the test aborts again, replace the circuit pack.
2012 ABORT Internal system error
2100 ABORT Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any FAIL The TN800 circuit pack is still detecting errors of this type. The
Error Code field contains the value of this counter.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, review the results of other tests
in the Long Test Sequence. Note the results of the Level 1
Status Inquiry test. Follow repair procedures for any of the
tests that fail. Otherwise, go to the next step.
3. If the tests for the endpoints or adjunct pass and the Layer
1 Transmission Error Counter Test continues to fail, check
the wiring to the endpoints or adjunct.
PASS The Layer 1 Transmission error counter was read correctly
and has a value of 0.
Continued on next page