Maintenance Object Repair Procedures
555-233-123
10-192 Issue 4 May 2002
Clear Error Counters Test (#270)
There are various error counters associated with each ASAI-PT. This test clears
those counters and triggers the auditing of Layer 3 reinitialization. This test is
used only to send messages to the ASAI-PT and, therefore, should neither abort
nor fail. ASAI uses a fixed TEI value of 1.
Table 10-64. TEST #270 Clear Error Counters
Error
Code
Te s t
Result Description/Recommendation
Any ABORT This test should never abort.
Any FAIL This test should never fail.
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS The message to clear the error counters of the ASAI-PT has
been sent.
Continued on next page