Maintenance Object Repair Procedures
555-233-123
10-204 Issue 4 May 2002
Synchronous Test Calls
You can initiate a synchronous outgoing test call (including a test call for
ISDN-PRI trunks) with these commands:
■ test trunk grp#/mbr# long [repeat #]
■ test board UUCSS long [repeat #]
■ test port UUCSSpp long [repeat #]
Table 10-72. TEST #258 ISDN Test Call
Error
Code
Tes t
Result Description/Recommendation
4 ABORT Signaling channel problem
1. Look for errors or alarms against the ‘‘ATM-SGRP (ATM
Signaling Group)’’ and ‘‘ATM-DCH (ATM D-Channel Port)’’
maintenance objects.
8 ABORT TN230x circuit-pack problem
1. See the ‘‘ATM-INTF (TN2305/6)’’ maintenance object.
1004 ABORT B-channel in use.
1. See if a call is active. Run status trunk grp#/mbr#
command.
2. If the service state is In-Service/Idle, retry the test.
1005 ABORT Bad configuration (for example, no Maintenance/Test circuit
pack)
1. Make sure that the Maintenance/Test Circuit Pack is inserted.
2. Repeat the test.
1018 ABORT Test call disabled
1. Enable Maintenance on the Trunk Group form.
1020 ABORT TN230x circuit-pack problem
1. See the ‘‘ATM-INTF (TN2305/6)’’ maintenance object.
1024 ABORT Maintenance/Test Digital Port in use
1. Wait until yellow and green LEDs on the Maintenance/Test
circuit pack are OFF.
2. Rerun the test.
3. If the problem persists, see the M/T-DIG (Maintenance/Test
Digital Port) maintenance object.
Continued on next page