ATM-BCH (ATM B-Channel Trunk)
Issue 4 May 2002
10-205 555-233-123
1113 ABORT Signaling link failed
1. Check the results of Test #255 (Signaling Link State Check
Test).
1116 ABORT Switch could not change the service state
1. See if calls are active. Run status trunk grp#/mbr#.
2. If a call is active. proceed as for Error Code 1119.
3. If not, check the Error and Alarm Logs and refer to the
ATM-TRK (Circuit Emulation Service Circuit Pack)
maintenance object.
1117 ABORT ISDN service message outstanding
1. Wait 2 minutes. Then try again.
1118 ABORT Far-end not administered
1. Check the administration of the far-end of the ATM trunk. Run
status trunk grp#/mbr#.
2. Try the test again.
1119 ABORT Test call aborted, normal call attempted
1. Wait for the call to terminate normally or drop it by running
busyout trunk grp#/mbr#.
2. When the trunk is idle, retry the test.
1120 ABORT Trunk OUT-OF-SERVICE/FAR-END
1. Try to change the service state via Test #256 (Service State
Audit Test).
2. Try the test again.
1122 ABORT No test-line number for the far-end switch
1. Check the Trunk Group Administration form.
1123 ABORT No Feature Access Code administration for this Facility Test
1. Check the Dial Plan and Feature Administration forms.
2000
2012
None
ABORT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2035 ABORT Call timed out
1. Wait 1 minute, and try again.
Table 10-72. TEST #258 ISDN Test Call — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page