Maintenance Object Repair Procedures
555-233-123
10-210 Issue 4 May 2002
Signaling Link Board Check (#643)
This nondestructive test checks the health of the ATM TN230X trunk circuit pack
hardware. The test runs on a periodic or scheduled basis, during initialization
testing, and upon demand.
NOTE:
The board-level maintenance is handled independently of the ATM-CES
signaling link maintenance, raising the possibility of inconsistent states.
Table 10-75. TEST #643 Signaling Link Board Check
Error
Code
Te st
Result Description/Recommendation
ABORT Internal System Error
Retry the command at 1-minute intervals for a maximum of 5
times.
8 FAIL The TN230X circuit pack is not in-service.
Check the Error Log for ATM-TRK errors and resolve any using
‘‘ATM-TRK (Circuit Emulation Service Circuit Pack)’’.
PASS The ATM TN230X circuit pack is in-service.
Continued on next page