RX2540 M4 Upgrade and Maintenance Manual 107
Basic software procedures
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
Ê Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
5.2.8 Enabling the boot watchdog
If the boot watchdog has been disabled for firmware upgrade purposes (see
section "Disabling the boot watchdog" on page 92), it has to be re-enabled to
complete the maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Enabling the boot watchdog in the BIOS
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under Boot Watchdog set the Action setting to Reset.
Ê Save your changes and exit the BIOS.
I For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Enabling the boot watchdog using the iRMC web interface
Ê Log in to the ServerView iRMC web interface.
Ê Select the Settings menu.
Ê Open the Server Management page.
Ê In the Boot Watchdog group, check the Enable Boot Watchdog option.
The Enable Boot Watchdog option must be selected.
Ê Select Reset from the Watchdog Action list.
Ê Click Apply for the changes to take effect.
I For more information on iRMC settings, see the iRMC user guides.