RX2540 M4 Upgrade and Maintenance Manual 99
Basic software procedures
5.2.2 Verifying system information backup/restore
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored from
the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the new
system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section "Viewing and clearing the System Event Log (SEL)" on
page 110).
After replacing the system board
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 110 to verify whether the backup data on
the Chassis ID EPROM has been restored to the system board:
Chassis IDPROM: Motherboard Exchange detected
Chassis IDPROM: BMC FW restore successful
Chassis IDPROM: BIOS restore successful
After replacing the front panel or Chassis ID EPROM
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 110 to verify whether a backup copy of
the system board settings has been transferred to the Chassis ID EPROM:
Chassis IDPROM: BMC FW backup successful