RX2540 M4 Upgrade and Maintenance Manual 355
Processor (CPU)
Ê "Reassembling" on page 63
Ê "Connecting the power cord" on page 67
Ê "Switching on the server" on page 70
I When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There is
no technical problem.
Proceed as follows:
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Ê Select the Save & Exit menu.
Ê Select Save Changes and Exit or Save Changes and Reset.
Ê Verify that the Global Error indicator stops flashing.
Ê "Resuming BitLocker functionality" on page 112
11.3 Replacing a CPU or heat sink
V CAUTION!
CPUs are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a CPU
has been removed from its protective sleeve or from its socket, place it
with its smooth side down on a non-conducting, antistatic surface. Never
push a CPU over a surface.
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver