386 Upgrade and Maintenance Manual RX2540 M4
Ê Install the memory module, see section "Installing a memory module" on
page 340.
Ê If applicable, install the memory spacers, see section "Installing a memory
spacer" on page 389.
Ê Close the required memory cooling unit(s).
Ê Position the memory cover(s) over the memory modules and press them
carefully down, see figure 261 on page 379.
12.4.1.4 Concluding steps
Ê If applicable, install the riser module, see section "Riser modules for GPGPU
cards (FL)" on page 82.
Ê "Reassembling" on page 63
Ê "Connecting the power cord" on page 67
Ê "Switching on the server" on page 70
Ê "Resuming BitLocker functionality" on page 112
12.4.2 Removing a memory module
12.4.2.1 Preliminary steps
Ê "Suspending BitLocker functionality" on page 91
Ê "Shutting down the server" on page 55
Ê "Disconnecting the power cord" on page 56
Ê "Getting access to the component" on page 58
Ê If applicable, remove the riser module, see section "Riser modules for
GPGPU cards (FL)" on page 82.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver (for the riser module)