154 Upgrade and Maintenance Manual RX2540 M4
Hard disk drives (HDD) and solid state drives (SSD)
7.3.7.1 Preliminary steps
Ê "Locating the defective server" on page 53
Ê "Locating the defective component" on page 54.
7.3.7.2 Removing the defective 3.5-inch HDD module
Ê Remove the HDD module, see section "Removing a 3.5-inch HDD module"
on page 152.
Ê If applicable, remove the HDD from the installation frame, see section
"Handling HDDs or SSDs without installation frame" on page 139.
7.3.7.3 Installing the new 3.5-inch HDD module
Ê If applicable, install the HDD in the installation frame, see section "Handling
HDDs or SSDs without installation frame" on page 139.
Ê Install the HDD module, see section "Installing 3.5-inch HDD modules" on
page 148.
7.3.7.4 Concluding steps
Ê If the HDD/SSD is configured using a RAID controller with a RAID level
higher than "0", the rebuild will start automatically, see section "Performing
a RAID array rebuild" on page 113.
7.3.8 Replacing the 3.5-inch HDD backplanes
7.3.8.1 Preliminary steps
Ê "Locating the defective server" on page 53
Ê "Shutting down the server" on page 55
Ê "Disconnecting the power cord" on page 56
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools: Phillips PZ2 / (+) No. 2 screw driver / hexagon screw driver 5 mm