568 Upgrade and Maintenance Manual RX2540 M4
Appendix A
# of
Beep
Description Action
1 Invalid password Ê Check for the correct password and try
again.
Ensure that the caps lock key is
deactivated.
5 No Console Input
devices1 or Output
devices2 are found
Booting will continue.
1 Serial console redirection is considered a
console output device if enabled.
2 Serial console redirection is considered a
console input device if enabled.
This beep code is only an information.
6 Flash update is failed A processing bar and an error message is
displayed on the screen.
This beep code is only an information.
8 Platform PCI resource
requirements cannot
be met
Ê Check the connection of your expansion
card whether it is installed in a correct
slot.
Ê Enter the BIOS setup menu.
Ê Open the Advanced menu.
Ê Check in the PCI Subsystem Settings
the parameter Above 4G Decoding.
This parameter must be set to Enabled.