Table 14-56 Instance attributes
Attrib‐
ute ID
Service
1)
Type Name Value/explanation
1 get UINT32 Interface Speed 0: link down,
10: 10 Mbps,
100: 100 Mbps
2 get Interface Flags Bit 1: Link-Status
Bit 2: Duplex Mode (0: Half du‐
plex, 1 duplex)
Bit 3…5: Automatic state iden‐
ti󹪝cation
Bit 6: Reset required
Bit 7: Local hardware fault
(0=ok)
3 get ARRAY Physical Address Ethernet MAC address
4 get,
get_and_clea
r
Struct of Interface Counters Optional, required if the "Media
Counters Attribute" is implemen‐
ted.
UINT32 In Octets Received octets
UINT32 In Ucast Packets Received Unicast packets
UINT32 In NUcast Packets Received non-Unicast packets
UINT32 In Discards Incoming packets, not processed
UINT32 In Errors Incoming packets with errors
UINT32 In Unknown Protos Incoming packets with unknown
protocol
UINT32 Out Octets Sent octets
UINT32 Out Ucast Packets Sent Unicast packets
UINT32 Out NUcast packets Sent non-Unicast packets
UINT32 Out Discards Outgoing packets, not processed
UINT32 Out Errors Outgoing packets, with errors
Functions