Attrib‐
ute ID
Service
1)
Type Name Value/explanation
5 get,
get_and_clea
r
Struct of Media Counters Media-speci󹪝c counters
UINT32 Alignment Errors Structure received, which does
not match the number of octets
UINT32 FCS Errors Structure received, which does
not pass the FCS check
UINT32 Single Collisions Structure successfully transmit‐
ted, precisely one collision
UINT32 Multiple Collisions Structure successfully transmit‐
ted, multiple collisions
UINT32 SQE Test Errors Number of SQE errors
UINT32 Deferred Transmissions First transmission attempt de‐
layed
UINT32 Late Collisions Number of collisions that occur‐
red delayed by 512 bit timers to
the request
UINT32 Excessive Collisions Transmission unsuccessful as a
result of intensive collisions
UINT32 MAC Transmit Errors Transmission unsuccessful as a
result of an internal MAC sublay‐
er transmission error.
UINT32 Carrier Sense Errors Number of errors when attempt‐
ing to send a request frame,
where the transmission condi‐
tion was lost or was not assigned
UINT32 Frame Too Long Structure too large
UINT32 MAC Receive Errors Transmission unsuccessful as a
result of an internal MAC sublay‐
er receive error.
6 get Struct of Interface Control
UINT16 Control Bits
UINT16 Forced Interface Speed
10 get String Interface_Label Interface-Label
11 get Interface Capability Bit 0: Manual Setting
Bit 1: Auto-negotiate
Bit 2: Auto-MDIX
Bit 3: Manual Speed/Duplex
Bits 4 – 31: reserved
Rest: Speed/Duplex options
1)
Supported services: Get attribute all, get attribute single