- 2261 -
1
Input/output terminals
Analog output 0 (AO 0)
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
AO 0
c0771[0]
(21)
AO0 (X132.10/11)
c0782[0]
(0)
AO0 (X132.10/11)
Analog output, activate
absolute value generation
0 ... 1
p0775[0] (0)
Analog output
smoothing time constant
0.0 ... 1000.0 [ms]
p0773[0] (0.0)
Analog output type
0 ... 2
p0776[0] (0)
Analog output
characteristic value x1
-1000.00 ... 1000.00 [%]
p0777[0] (0.00)
Analog output
characteristic value x2
-1000.00 ... 1000.00 [%]
p0779[0] (100.00)
Analog output characteristic value y2
0.000 ... 20.000
p0780[0] (20.000)
Analog output offset
-20.000 ... 20.000
p0783[0] (0.000)
-1
0
1
0
1
Analog output actual output value
referred [%]
r0772[0]
x
1
y
2
x
2
y
1
y
x
[%]
Analog output characteristic value y1
0.000 ... 20.000
p0778[0] (0.000)
x
y
[%]
2
0, 1
4 mA
0
D
A
+
<1>
+
Analog output actual output voltage/current
r0774[0]
0 … 10 V
0 … 20 mA
M
Voltage output
Current output
%
x
2
x
1
x
1
· 100 %
x
2
Reference quantities, e. g.
p2000 … r2004
Sampling time of the analog
outputs:
p0799[2] (4 ms)
For p0776[0] = 1 the unit is V.
For p0776[0] = 0, 2 the unit is mA.
<1>
<1>
<1>
<1>
Figure14-40 2261 - Analog output 0 (AO 0)
Functions
14.8Inputs/outputs
SINAMICS G220 converter
430 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB