- 3080 -
1
Setpoint channel
Ramp-function generator selection, status word, tracking
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
<5>
1
n_set_4
n_set_5
Ramp-function generator selection
p1115 (1)
r1150
Ramp-function generator speed
setpoint at the output [rpm]
t
x,y x
y
t
x,y x
y
T1
T1
<4>
+
+
x
x
y
y
+
+
<5>
&
1
0
c1160 [C]
(0.00)
Speed controller speed setpoint 2 [rpm]
c1155 [C]
(0.00)
Speed controller speed
setpoint 1 [rpm]
r1169
Speed controller speed setpoints
1 and 2 [rpm]
r1170
Speed controller setpoint
sum [rpm]
Ramp-function generator tracking intensity
p1145 [D] (0.0)
<2>
<3>
<2>
[2501.7]
r1199.01 = Ramp-up active
r1199.11 = Ramp-down active
r1199.21 = Ramp-function generator active
r1199.31 = Ramp-function generator set
r1199.41 = Ramp-function generator held
r1199.51 = Ramp-function generator tracking active
r1199.61 = Maximum limit active
r1199.71 = Ramp-function generator acceleration positive
r1199.81 = Ramp-function generator acceleration negative
r1199
r1199.0..8
Ramp-function generator status word
For p1145 > 0, ramp-function generator tracking is activated when the torque limiting
responds.
This means that the speed controller output only exceeds the torque limit by a
deviation that can be set via p1145.
For OFF1/OFF3, the ramp-function generator ramp is active. The ramp-function
generator is set to the setpoint (r1170) and stops the drive with the ramp-downtime
(p1121 or p1135). STW1.4 (enable ramp-function generator) is effective while the
drive is stopped via the ramp-function generator.
Depending on the p1115, the basic ramp-function generator [3060] or the extended
ramp-function generator [3070] is effective.
If technology controller is activated (c2200 > 0, p2251 = 1) interconnected with r2294.
Behavior of the response ramp of the torque limiting:
p1145 = 0.0: No ramp-function generator tracking. The ramp-function generator ramp is no longer in the range of the speed actual value.
p1145 = 1.0: The ramp-function generator ramp remains as close as possible to the speed actual value.
p1145 > 1.0: The ramp-function generator ramp is steeper than for p1145 = 1.0 (higher "speed following error").
The value is displayed correctly only with r0899.2 = 1 (operation enabled).
<3>
<4>
<2>
<1>
1
2
3
4
5
6
7
8
Bit
0
c2148
<1>
[3051.8]
[3060.8], [3070.8]
Ramp-function generator selection
Ramp-function generator status word
Ramp-function generator tracking
1
0
[3060.8]
[3070.8]
r1199.5
1 = Ramp-function
generator tracking active
Ramp flattening-off
[3060.4]
[3070.4]
r0898.6
1 = Enable speed setpoint
1
0
0
0
r0898.4
1 = Enable ramp-function generator
1
0
[2501.7]
[2522.7]
[7010.7]
From the ramp-
function generator
friction characteristic
Plot friction characteristic
No OFF2
No OFF3
[3050.1]
[6030.1]
[6822.1]
[8011.1]
r1407.7
1 = Torque limit reached
From Extended ramp-function generator
From Basic ramp-function generator
Figure14-75 3080‑Ramp-function generator selection, status word, tracking
Functions
14.9Setpoint channel
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 461