- 8020 -
1
Signals and monitoring functions
Motor temperature status word faults/alarms
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
01
00
02
03
04
05
08
... Reserved
Bit No. Meaning
r5389
r5389.0..8
Mot_temp status word faults/alarms
r5389.01 = Motor temperature measurement fault present
r5389.11 = Motor temperature model fault present
r5389.21 = Encoder temperature measurement fault present
r5389.41 = Motor temperature measurement alarm active
r5389.51 = Motor temperature model alarm active
r5389.81 = Current reduction active
... Reserved
[8016.8] A07910
[8017.8], [8019.8] A07012
[8016.8] A07910
[8016.8]
r5389.31 = Motor overload protection fault active
r5389.71 = Motor overload protection alarm active
07
A07012
[8016.8] F07011
F07011
Figure14-216 8020 - Motor temperature status word faults/alarms