Checksums
Using the checksums, it can be identi󹪝ed as to whether the con󹪝guration and/or
parameterization of Safety Integrated was changed.
An acceptance test is required after changing the checksums. The system outputs the
appropriate messages to indicate that an acceptance test is required. The checksums are
used for documentation purposes within the scope of an acceptance test.
The parameterization can be transferred to several devices by separating the checksums for
function and communication. When transferring the parameterization to several devices, you
must check whether the device is correctly assigned in the communication group.
More information
Further information about the checksums is provided in the parameter list.
Parameters
The following list contains the parameters for "Function status/diagnostics".
Number Name Unit
r9722.0...15 SI status signals
r9780[0...1] SI checksum to check changes
r9781[0...1] SI change control time stamp days
r9782[0...1] SI change control time stamp milliseconds [ms]
r9796 SI actual checksum PROFIsafe addresses
p9797 SI reference checksum PROFIsafe addresses
r9798 SI actual checksum over the drive con󹪝guration
p9799 SI reference checksum over the con󹪝guration of the drive
Overview
The machine manufacturer is responsible in ensuring that the plant or machine functions
perfectly. As a consequence, after commissioning, the machine manufacturer must check those
functions which represent an increased risk of injury or material damage, or have them checked
by specialist personnel. This acceptance or validation is speci󹪝ed in the European Machinery
Directive and comprises 2 parts:
Acceptance test: Check the safety-relevant functions and machine parts after
commissioning.
Documentation: Generate an "Acceptance report" that describes the test results.
ISO13849‑1 provides additional information relating to validation, for example. The
acceptance test requirements (con󹪝guration check) for the safety functions of electric drives
are based on IEC61800-5-2.