Description
Acceptance test of the machine or plant
The acceptance test checks whether the safety-relevant functions in the plant or machine
function correctly. The documentation of the components used in the Safety Integrated
Functions can also provide information about the tests required. Testing the safety-relevant
functions includes, e.g. the following:
• Is all safety equipment, such as protective door monitoring devices, light barriers or
EMERGENCY STOP buttons, connected and ready for operation?
• Does the higher-level control respond as expected to the safety-relevant feedback signals of
the drive?
• Do the drive settings match the congured safety-relevant function in the machine?
Acceptance test of the converter
The acceptance test of the converter is a part of the acceptance test of the entire machine or
plant.
The acceptance test of the converter veries whether Safety Integrated Functions have been
set to match the congured Safety Functions of the machine. The acceptance test documents
the settings with which the real function fullls the intended functionality.
Documentation
The documentation encompasses the following:
• Result of the acceptance tests
• Settings of the Safety Integrated Functions
The documentation must be signed.
Persons authorized to perform the acceptance test
Personnel from the machine manufacturer, who, on account of their technical qualications
and knowledge of the safety functions, are in a position to perform the acceptance test in the
correct manner are authorized to perform the acceptance testing of the converter and the
motor.
Functions
14.12Safety Integrated
SINAMICS G220 converter
708 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB