Figure15-7 Movement of acknowledged faults to the fault history
Parameters
The following list contains the parameters of the "Fault buer and fault history" function.
Number Name Unit
r0945[0...63] Fault code
r0948[0...63] Fault time received in milliseconds [ms]
r0949[0...63] Fault value
p2100[0...19] Change fault response fault number
p2101[0...19] Change fault response response
r2109[0...63] Fault time removed in milliseconds [ms]
p2118[0...19] Change message type message number
p2119[0...19] Change message type type
r2130[0...63] Fault time received in days
r2131 Actual fault code
r2133[0...63] Fault value for oat values
r2136[0...63] Fault time removed in days
r3120[0...63] Component fault
r3122[0...63].0...20 Diagnostic attribute fault
System messages
15.8Fault buer
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 751