Replacing a Drum Cartridge
You need to replace a drum cartridge if it has reached the end of its component life, if it is damaged by light, or if
you are experiencing spots and streaks on your output.
Note: All four Drum cartridges are interchangeable.
Note: After replacing the drum cartridge, the system automatically resets the usuage counter of this CRU
component to zero (0). Check the Consumables screen for the reset and new status.
Caution: Drums are light sensitive. Do not leave the Drum Cartridge Drawer open for more than one
minute. Exposing the drum cartridges to direct sunlight or strong light from indoor fluorescent lighting for
more than one minute can cause image quality defects.
Caution: Replace drum cartridges while the press is powered ON.
1. Ensure that the press is stopped and is not currently printing jobs.
2. Open the press Front Door.