Installation & Operation Manual 182 Document # LTRT-92224
Mediant 8000
12. Wait up to 10 minutes until the ES board in slot 19 completes the restart and
returns to service. Use the following command to determine whether the ES
board has completed the restart. Value Enabled(1) indicates that the board is
back in service:
SC-1 -- ~ -- /moGW
show esboard#19 param OperationalState
OperationalState=Enabled(1)
13. If after completing the above procedure, there is still no network connectivity
between the EMS server and the Mediant 8000, contact the on-site network
administrator and verify that the physical network topology and configuration of
the external Layer 3 Switches / Routers to which the Mediant 8000 is connected