Parameter
Name
Type
Provision
ing Type
Description
SBC
Survivability
Registration
Time [Sec]
Integer
0 - 2,000,000
Instant Defines the duration of the
periodic registrations between the
user and SBC, when the SBC is in
survivability state (i.e., when
REGISTER requests cannot be
forwarded to the proxy, and is
terminated by the SBC). When set
to 0, the SBC uses the value of
the parameter
SBCUserRegistrationTime for the
SBC response.
The valid range is 0 to 2,000,000
seconds.
Keep
original user
in Register
Enum
Disable,EnableDisable, Enable
Instant Determines whether the device
replaces the Contact user with a
unique Contact user in the
outgoing message in response to
a REGISTER request.
[0] Disable = (default) The
device replaces the original
Contact user with a unique
Contact user, for example:
Received Contact:
<sip:123@domain.com
>
Outgoing (unique) Contact:
<sip:FEU1_7_1@SBC
>
[1] Enable = The original
Contact user is retained and
used in the outgoing
REGISTER request.