Installation & Operation Manual 886 Document # LTRT-92224
Mediant 8000
2. Configure the Global IP address to be used by the active SC board as described
in 'Performing Basic Configuration of the Mediant 8000 Software' on page 146 .
When prompted, provide the allocated IP address in OAM subnet – e.g.
10.8.1.10.
3. Connect to the CLI interface on the Active SC board (typically located in Slot 1).
Use Global IP Address if you establish connection via SSH/Telnet. Use the RS-
232 serial console if IP connectivity with the Mediant 8000 is unavailable. For
more information, see 'Connecting to the CLI via an RS-232 Serial Console' on
page 109.
4. Login as a CLI user with administrative privileges (e.g. acladmin). For more
information, see 'Logging into the Command Line Interface' on page 115.
5. Lock the Media Gateway via the following command (note that this will stop all
services provided by the Media Gateway):
SC-1 -- ~ -- /moGW
• lock
Do you really want to lock /moGW [y/n] y
Performing lock action on /moGW - OK!
6. For the ES/6600 switch only: Configure the Media Gateway’s interface
separation settings (single interface, three VLANs in use):
modify Interfaces=0
modify MediaAggregationEnable=0
modify OAMTagId=8
add moVlanTag#1
modify moVlanTag#1 VLANTagID=6
add moVlanTag#2
modify moVlanTag#2 VLANTagID=7
7. Configure three IP subnets available on site: