Version 6.6 887 October 2014
Installation & Operation Manual A. Examples of IP Network Connectivity Configuration
add moSubnet#2
modify moSubnet#2 SubnetIP=10.6.0.0
modify moSubnet#2 SubnetPrefixBitsLength=16
modify moSubnet#2 DefaultGW=10.6.0.1
modify moSubnet#2 VLANTagID=6
add moSubnet#3
modify moSubnet#3 SubnetIP=10.7.0.0
modify moSubnet#3 SubnetPrefixBitsLength=16
modify moSubnet#3 DefaultGW=10.7.0.1
modify moSubnet#3 VLANTagID=7
add moNetworkProfile#1/moNetworkSubnet#2
modify moNetworkProfile#1/moNetworkSubnet#2 SubnetIndex=2
add moNetworkProfile#1/moNetworkSubnet#3
modify moNetworkProfile#1/moNetworkSubnet#3 SubnetIndex=3
8. Configure the Media Gateway board’s IP Addresses:
modify moBoard#11/moBoardIPAddress#1=10.6.1.20
modify moBoard#11/moBoardIPAddress#2=10.7.1.20
modify moBoard#11/moBoardIPAddress#3=10.8.1.20
modify moBoard#12/moBoardIPAddress#1=10.6.1.21
modify moBoard#13/moBoardIPAddress#2=10.7.1.21
modify moBoard#14/moBoardIPAddress#3=10.8.1.21
9. Activate new network configuration by unlocking the Media Gateway :
SC-1 -- ~ -- /moGW
unlock
Performing unlock action on /moGW - OK!
10. The new network configuration will be activated. Media Gateway boards will be
reset and their Operational State will be changed to Disabled (boards will be
displayed as Red in the EMS GUI).
It may take up to 5 minutes for all Media Gateway boards to complete the restart.
When the Media Gateway board returns to service, its Operational State will be
changed to Enabled and the board's color will be displayed as Green in the EMS
GUI.