Routine Maintenance Procedures
555-233-123
5-92 Issue 4 May 2002
Enter show signaling cause causecode on the A500 console. Screen
5-30 shows the screen output for this command.
Screen 5-30. A500:show signaling cause 31
3. At the DEFINITY SAT type display errors and press
Enter.
Set the Error List to errors and Category to PNC on the input screen
(Screen 5-31) and press Enter to display any Cause Codes (see Table 5-10
on page 5-93 below) returned from the ATM network to a TN230X on the
PPN (and to a TN230X on an EPN). This is successful only if the links
between the PPN and the EPN remain up so that the message from the
EPN is logged.
Refer to ‘‘ATM-BCH (ATM B-Channel Trunk)’’ for detailed information
regarding Cause Codes for this Maintenance Object.
Screen 5-31. DEFINITY display errors Input Screen
A500:show signaling cause 31
Cause 31: Normal, unspecified
display errors Page 1 of 1 SPE A
ERROR REPORT
The following options control which errors will be displayed.
ERROR TYPES
Error Type: Error List: errors
REPORT PERIOD
Interval: a From: / / : To: / / :
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet:
Port Network:
Board Number:
Port:
Category: PNC
Extension:
Trunk ( group/member ): /