Maintenance Object Repair Procedures
555-233-123
10-1360 Issue 4 May 2002
Table 10-502. TEST #1281 TCP/IP Ping Test
Error
Code
Te s t
Result Description/Recommendation
1, 2, 7,
11
ABORT Internal error
1. Retry the command at 1-minute intervals up to 3 times
2. Escalate if the problem persists.
1005 ABORT Test configuration is incorrect.
1. Verity PPP link is in-service (status clan-port UUCSSpp or
status link n).
2. Repeat the test.
3. Escalate if the problem persists.
1124 ABORT ppp link is not enabled.
1. Verify that the ppp link is enabled (status port UUCSSpp,
status link n, or display data-module).
2. If the link is not enabled, enable the link (change
data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT PPP link not in service.
1. Verify whether ppp link is in service (status port UUCSSpp
or status link n).
2. If the ppp link is not in service, release the link (release link
n or release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
2000 ABORT Response to the test was not received from the CLAN circuit
pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit
pack if the other ports on the board are not in use (Yellow
LED is off). Reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Continued on next page