Maintenance Object Repair Procedures
555-233-123
10-1554 Issue 4 May 2002
2025
(contd.)
ABORT If none of the three red LEDs is on AND if this is the fourth
attempt to clear the problem (that is, the Standby SPE
Processor, Standby SPE Memory, and carrier A Duplication
Interface circuit packs have already been replaced), proceed
with Step 10.
If none of the three red LEDs is on AND if this is the fifth
attempt to clear the problem (the Standby SPE Processor,
Standby SPE Memory, and carrier A Duplication Interface
circuit packs have been replaced and the test has been
repeated once), escalate the problem.
10. Issue refresh spe-standby to put the Standby SPE into
Standby Mode. This command may have to be issued multiple
times. If refresh spe-standby successfully completes 5 times
without the Standby SPE becoming labeled standby on the
status system form, wait 20 minutes. This does not include
cases where the command completes with the terminal
message line errors Refresh not successful; use display
errors to check for STBY-SPE errors or Cannot interrupt
Standby SPE while entering maintenance mode; please try
later. Issue the refresh spe-standby command once more. If
the Standby SPE is not labeled standby on the status system
form after this attempt, use the busyout spe-standby and
release spe-standby command to put the standby into standby
mode.
11. Repeat the command.
12. Issue test spe-standby long.
Table 10-578. Test Result Error Codes Associated with the Standby SPE Continued