Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-148 Issue 4 May 2002
test tone-clock
Help Messages
If the system technician presses HELP after entering test tone-clock the following
message appears:
Enter [[cabinet(1-3)];carr(A-B)],[long or short],
[repeat (1-100) or clear], [schedule]
Error Messages
If an identifier greater than 3 (three) characters is entered, or the cabinet entered
is not a digit (number), the following message appears:
Identifier invalid
If the carrier entered is invalid, the following message appears:
Invalid carrier specified
If the cabinet entered is not within the valid range of cabinets or the cabinet is not
administered, the following message appears:
Cabinet number not assigned
If there is no tone/clock board at the specified location, one of the following
messages appears:
Board not inserted
Board not assigned
If the specified cabinet carrier location is that of a switch node, the following
message appears:
Switch Node carrier specified; invalid command for SN carrier
If the cabinet carrier location entered is that of an EPN that is not available, the
following message appears:
EPN is not available
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
login id:command has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later