Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-56 Issue 4 May 2002
Output
After you complete the options screen, the system displays a 1- or 2-page Alarm
Report. To toggle between the pages and to exit the report, use the keys
described below:
■ For 513 and 715 terminals, use F8 for NEXT PAGE and PREV PAGE
commands
■ For all other terminals, use F7 for NEXT PAGE and PREV PAGE commands
■ Use Esc for the CANCEL command
The figure below is an example of an Alarm Report.
Field descriptions
Port
Lists the location codes for the alarmed object, as follows:
■ Circuit packs locations display as:
cabinet-carrier-[slot]-[circuit]. Example: 01C0702.
■ Port network locations display as: port network number-bus.
Example: PN 02B. PN 02 = Port Network (PN) number and
A or B = bus.
■ Fiber link locations display as: fiber link number-PNC side.
Example: x A-PNC. “X” = fiber link number and “A” = PNC
side [A or B].
Maintenance
Name
Lists the logical name of the maintenance object with the alarm.
On Brd
A y (yes) indicates the fault was found on the associated circuit
pack. An n (no) indicates the fault is not connected to the circuit
pack.
display alarms
ALARM REPORT
Port Maintenance On Alt Alarm Svc Ack? Date Date
Name Brd? Name Type State 1 2 Alarmed Resolved
02A TONE-BD y MAJOR y n 05/22/20:34 00/00/00:00
01C07 ANL-BD y MINOR n n 05/22/20:26 00/00/00:00
01C0702 ANL-LINE n 311 WARNING IN 05/22/20:26 00/00/00:00
01C0701 ANL-LINE n 1051 WARNING IN 05/22/20:26 00/00/00:00
01C0703 ANL-LINE n 1053 WARNING IN 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
01C1505 CO-TRK n 78/01 WARNING OUT 05/22/20:26 00/00/00:00
02A0201 TONE-PT n WARNING 05/22/20:34 00/00/00:00
02A TDM-CLK n WARNING 05/23/13:43 00/00/00:00
PN 02B TDM-BUS n WARNING 05/23/14:53 00/00/00:00
Command successfully completed