Looparound Test (#161)
This test checks the on-board transmission capabilities of the NPE, the codec,
and the battery feed chip of the analog port. The test passes if the signal
measured by the tone detector is within acceptable limits.
Table 10-23. TEST #161 Looparound Test
Error
Code
Te s t
Result
Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the
service state of the port.
3. If the port is in use, wait until the port is idle and retry the
command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, retry the command at 1-minute intervals a
maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.