424
Magellan™ 9800i Scanner
MSI Length Con-
trol
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
MSI Length 1
04 04 04 04 04 04
MSI Length 2
16 16 16 16 16 16
MSI Stitching
00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable)
Standard 2 of 5
Enable
00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable)
Standard 2 of 5
Check Character
Calculation
00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable)
Standard 2 of 5
Check Character
Transmission
01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable)
Standard 2 of 5
Minimum Read
01 (1 read) 01 (1 read) 01 (1 read) 01 (1 read) 01 (1 read) 01 (1 read) 01 (1 read) 01 (1 read)
Standard 2 of 5
Correlation
00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable)
Standard 2 of 5
Length Control
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
Standard 2 of 5
Length 1
08 08 08 08 08 08 08 08
Standard 2 of 5
Length 2
50 50 50 50 50 50 50 50
Standard 2 of 5
Stitching
00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable)
2D Symbology Programming
Data Matrix Enable
00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable) 00 (disable)
Data Matrix Length
Control
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
Set Data Matrix
Length 1
0001 0001 0001 0001 0001 0001 0001 0001
Set Data Matrix
Length 2
0800 0800 0800 0800 0800 0800 0800 0800
PDF 417 Enable
01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable) 01 (enable)
PDF 417 Length
Control
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
00
(variable)
Set PDF 417
Length 1
0001 0001 0001 0001 0001 0001 0001 0001
Set PDF 417
Length 2
2710 2710 2710 2710 2710 2710 2710 2710
PDF 417 Read
Option
00 (none) 00 (none) 00 (none) 00 (none) 00 (none) 00 (none) 00 (none) 00 (none)
Feature
Default
Master
RS-232
RS-232
Wincor-
Nixdorf
RS-232
Single
Cable
Keyboard
USB COM
/
USB TEC
USB
OEM
IBM
Port 17
Port 9B
Port 5B

Table of Contents