2-25
getting no response in the specified period of time, the NAS buffers and resends the packet until it
receives a response or the number of transmission retries reaches the configured limit. In the latter case,
the NAS discards the packet.
Note that you can use the commands to change the setting only when no user is using the RADIUS
scheme.
Related commands: reset stop-accounting-buffer, radius scheme, display
stop-accounting-buffer.
Examples
# In RADIUS scheme radius1, enable the device to buffer the stop-accounting requests getting no
responses.
<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] stop-accounting-buffer enable
timer quiet (RADIUS scheme view)
Syntax
timer quiet minutes
undo timer quiet
View
RADIUS scheme view
Default Level
2: System level
Parameters
minutes: Primary server quiet period, in minutes. It ranges from 1 to 255 and defaults to 5.
Description
Use the timer quiet command to set the quiet timer for the primary server, that is, the duration that the
status of the primary server stays blocked before resuming the active state.
Use the undo timer quiet command to restore the default.
Related commands: display radius scheme.
Examples
# Set the quiet timer for the primary server to 10 minutes.
<Sysname> system-view
[Sysname] radius scheme test1
[Sysname-radius-test1] timer quiet 10

Table of Contents

Other manuals for H3C S5120-SI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5120-SI Series and is the answer not in the manual?

H3C S5120-SI Series Specifications

General IconGeneral
BrandH3C
ModelS5120-SI Series
CategorySwitch
LanguageEnglish

Related product manuals