1-17
Field Description
RX power low Incoming (RX) power level is low.
display transceiver diagnosis
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
View
Any view
Default Level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays the currently measured value of digital diagnosis
parameters of the H3C customized anti-spoofing pluggable optical transceiver plugged in the specified
interface. interface-type interface-number represents interface type and interface number. If it is not
specified, the command displays the currently measured value of digital diagnosis parameters of H3C
customized anti-spoofing pluggable optical transceivers in all the interfaces.
Description
Use the display transceiver diagnosis command to display the currently measured value of digital
diagnosis parameters of H3C customized anti-spoofing pluggable optical transceivers.
Examples
# Display the currently measured value of the digital diagnosis parameters of the H3C customized
anti-spoofing pluggable optical transceiver plugged in interface GigabitEthernet1/0/25. (The output of
this command varies with devices.)
<Sysname> display transceiver diagnosis interface GigabitEthernet1/0/25
GigabitEthernet1/0/25 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 1-9 display transceiver diagnosis command output description
Field Description
transceiver diagnostic information
Digital diagnosis information of the transceiver
plugged in the interface
Current diagnostic parameters Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in °C, with
the precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with the
precision to 0.01 V.

Table of Contents

Other manuals for H3C S5120-SI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5120-SI Series and is the answer not in the manual?

H3C S5120-SI Series Specifications

General IconGeneral
BrandH3C
ModelS5120-SI Series
CategorySwitch
LanguageEnglish

Related product manuals