1-18
Field Description
Bias(mA)
Digital diagnosis parameter-bias current, in mA, with
the precision to 0.01 mA.
RX power(dBM)
Digital diagnosis parameter-RX power, in dBM, with
the precision to 0.01 dBM.
TX power(dBM)
Digital diagnosis parameter-TX power, in dBM, with
the precision to 0.01 dBM.
display transceiver
Syntax
display transceiver interface [ interface-type interface-number ]
View
Any view
Default Level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays main parameters of the pluggable transceiver
plugged in the specified interface. interface-type interface-number represents interface type and
interface number. If it is not specified, the command displays main parameters of the pluggable
transceiver(s) in all the interfaces.
Description
Use the display transceiver command to display main parameters of a single or all pluggable
transceivers.
Examples
# Display main parameters of the pluggable transceiver plugged in interface GigabitEthernet1/0/25.
(The output of this command varies with devices.)
<Sysname> display transceiver interface GigabitEthernet1/0/25
GigabitEthernet1/0/25 transceiver information:
Transceiver Type : 1000_BASE_SX_SFP
Connector Type : LC
Wavelength(nm) : 850
Transfer Distance(m) : 550(50um),270(62.5um)
Digital Diagnostic Monitoring : YES
Vendor Name : H3C
Ordering Name : SFP-GE-SX-MM850
Table 1-10 display transceiver command output description
Field Description
transceiver information Pluggable transceiver information