1-13
Parameters
hop-value: Maximum hop for collecting topology information, in the range 1 to 16.
Description
Use the ntdp hop command to set maximum hop for collecting topology information.
Use the undo ntdp hop command to restore the default.
By default, the value is 3.
Note that this command is only applicable to the topology-collecting device. A bigger number of hops
requires more memory of the topology-collecting device.
Examples
# Set the hop count for topology information collection to 5.
<Sysname> system-view
[Sysname] ntdp hop 5
ntdp timer
Syntax
ntdp timer interval
undo ntdp timer
View
System view
Default Level
2: System level
Parameters
interval: Interval (in minutes) to collect topology information, in the range 0 to 65,535. The value 0
means not to collect topology information.
Description
Use the ntdp timer command to configure the interval to collect topology information.
Use the undo ntdp timer command to restore the default.
By default, the interval to collect topology information is 1 minute.
Note that the management device can start to collect the topology information only after the cluster is
set up.
Examples
# Set the interval to collect the topology information to 30 minutes.
<Sysname> system-view
[Sysname] ntdp timer 30

Table of Contents

Other manuals for H3C S5120-SI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5120-SI Series and is the answer not in the manual?

H3C S5120-SI Series Specifications

General IconGeneral
BrandH3C
ModelS5120-SI Series
CategorySwitch
LanguageEnglish

Related product manuals