Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit
hotspot 1 45 NA 85 95 NA
display fan
Syntax
display fan [ fan-id ]
View
Any view
Default Level
1: Monitor level
Parameters
fan-id: Displays the operating state of the specified fan, where fan-id represents the built-in fan number.
Description
Use the display fan command to display the operating state of built-in fans.
Examples
# Display the operating state of all fans in a device.
<Sysname> display fan
Fan 1 State: Normal
display memory
Syntax
display memory
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the display memory command to display the usage of the memory of a device.
Examples
# Display the usage of the memory of a device.
<Sysname> display memory
System Total Memory(bytes): 83947760
Total Used Memory(bytes): 24881784