EasyManuals Logo

H3C S5120-SI Series Command Reference

H3C S5120-SI Series
910 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #869 background imageLoading...
Page #869 background image
1-12
Examples
# Set the PD disconnection detection mode to dc.
<Sysname> system-view
[Sysname] poe disconnect dc
poe enable
Syntax
poe enable
undo poe enable
View
PoE interface view, PoE-profile file view
Default Level
2: System level
Parameters
None
Description
Use the poe enable command to enable PoE on a PoE interface.
Use the undo poe enable command to disable PoE on a PoE interface.
By default, PoE is disabled on a PoE interface.
z If a PoE configuration file is already applied to a PoE interface, you need to remove the
application of the file to the PoE interface before configuring the interface in PoE-profile view.
z If a PoE configuration file is applied to a PoE interface, you need to remove the application of the
file to the PoE interface before configuring the interface in PoE interface view.
Examples
# Enable PoE on a PoE interface.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] poe enable
# Enable PoE on a PoE interface through a PoE configuration file.
<Sysname> system-view
[Sysname] poe-profile abc
[Sysname-poe-profile-abc-1] poe enable
[Sysname-poe-profile-abc-1] quit

Table of Contents

Other manuals for H3C S5120-SI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S5120-SI Series and is the answer not in the manual?

H3C S5120-SI Series Specifications

General IconGeneral
BrandH3C
ModelS5120-SI Series
CategorySwitch
LanguageEnglish

Related product manuals