Issue 4.0
SV9100 Programming Manual 2-145
Description
Use Program 12-08 : Night Mode Service Range to define the changing range of toggle key for each
Day/Night Mode.
Example:
When Program 12-08 is set to 3 and the Mode Key is pressed (SC 751, 09 +0), the following modes are
switched:
Press once = Night
Press twice = Mid-night
Press third = Day
Default = 2
Conditions
None
Feature Cross Reference
Night Service
Program 12 : Night Mode Setup
12-08 : Night Mode Service Range
Level:
IN
Input Data
Night Mode Service Group Number 01~32
Item No. Range
01 2~8
(default = 2)