Issue 4.0
SV9100 Programming Manual 2-709
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.
Program 81 : Basic Hardware Setup for Trunk
81-08 : T1 Trunk Timer Setup
Level:
IN
Input Data
Item Name Input Data Default
01
Answer Signal Detection Time
(Loop)
1~250
(4ms ~ 1000ms)
15
60ms
02
Answer Signal Detection Time
(Ground)
1~250
(4ms ~ 1000ms)
15
60ms
03
Answer Signal Detection Time
(DID)
1~250
(4ms ~ 1000ms)
15
60ms
04
Answer Signal Detection Time
(E&M)
1~250
(4ms ~ 1000ms)
15
60ms
05
Answer Signal Detection Time
(OPX)
1~250
(4ms ~ 1000ms)
15
60ms
06
Clear Signal Detection Time
(Loop)
1~255
(100ms ~ 25500ms)
6
600ms
07
Clear Signal Detection Time
(Ground)
1~255
(100ms ~ 25500ms)
6
600ms
08
Clear Signal Detection Time
(DID)
1~255
(100ms ~ 25500ms)
6
600ms
09
Clear Signal Detection Time
(E&M)
1~255
(100ms ~ 25500ms)
6
600ms
10
Clear Signal Detection Time
(OPX)
1~255
(100ms ~ 25500ms)
6
600ms
11
Ringing Signal Detection Time
(Loop)
1~250
(8ms ~ 2000ms)
10
80ms
12
Ringing Signal Detection Time
(Ground)
1~250
(8ms ~ 2000ms)
10
80ms
13
Ringing Signal Detection Time
(DID)
1~250
(8ms ~ 2000ms)
10
80ms