SV9100 Programming Manual 2-649
Program: 51
Description
Use Program 51-01 : NetLink System Property Setting to define the parameters of the NetLink
feature.
Program 51 : NetLink Service
51-01 : NetLink System Property Setting
Level:
IN
IMPORTANT
Each system must be set with its own information.
When the NetLink System ID is changed (Item 01), the system must be reset.
Input Data
Item
No.
Item Input Data Default
01
NetLink System ID
This is the ID of each NetLink system. Setting should insure
that no overlap occurs between nodes.
0~50
(0 = No operation)
0
02
Primary Candidate Order
When the Primary system is turned off or disconnected from
network, this value is used to select a new Primary system.
Smaller number is higher priority.
If this value is the same number, the System ID (PRG51-01-01)
is referred, and the system which has the smaller number is
selected as Primary system.
1~50
30
03
Secondary System Flag
0: NetLink is dynamically established based on Node List in
PRG51-03-01.
Primary System is selected in the order which the system
wakes up.
1: The system connects with Top Priority Primary System.
If Top Priority Primary System was not found, the system
searches Primary System like this setting is 0.
0 = Disable
1 = Enable
0