Issue 4.0
SV9100 Programming Manual 2-415
Description
For systems that use Toll Restriction, use Program 25-11 : DISA Toll Restriction Class to assign a Toll
Restriction Class (1~15) to each DISA user (1~15). The system uses the Toll Restriction Class you enter
in Program 21-05 and 21-06. The Toll Restriction Class assigned to a DISA call is based on the DISA
Class of Service and user, which is determined by the password the caller dials.
When programming, make a separate entry for each Night Service mode.
Conditions
Program 21-05 cannot be used to assign Toll Restriction to DISA trunks.
Feature Cross Reference
Direct Inward System Access (DISA)
Program 25 : VRS/DISA Setup
25-11 : DISA Toll Restriction Class
Level:
IN
Input Data
DISA User Number 1~15
Item
No.
Day/Night
Mode
Toll
Restriction
Class
Default
01 1~8 1~15 2

Table of Contents

Other manuals for NEC Univerge SV9100

Questions and Answers:

NEC Univerge SV9100 Specifications

General IconGeneral
VoIP SupportYes
VoIP ProtocolsSIP, H.323
VoicemailIntegrated voicemail
NetworkingYes, via IP
Unified CommunicationsYes
MobilitySupports mobile extensions and applications
TypeIP-PBX
Network InterfacesGigabit Ethernet
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
WeightVaries depending on chassis and expansion cards

Related product manuals