Program: 14
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for each trunk port. Refer to the
table below for a description of each option, its range and default setting.
Program 14 : Trunk, Basic Setup
14-01 : Basic Trunk Data Setup
Level:
IN
Input Data
Trunk Port Number 001~400
Item
No.
Item Input Data Default
Related
Program
01
Trunk Name
Set the names for trunks. The
trunk name displays on a
multiline terminal for incoming
and outgoing calls.
Up to 12 Characters
Line 001
Line 002
Line 003
:
Line 400
02
Transmit Level
Select the CODEC gain for the
trunk. The option sets the gain
(signal amplification) for the trunk
you are programming.
1~57
(-15.5dB~+12.5dB in 0.5dB intervals)
32 (0dB)
03
Receive Level
Select the CODEC gain for the
trunk. The option sets the gain
(signal amplification) for the trunk
you are programming.
1~57
(-15.5dB ~ +12.5dB in 0.5dB intervals)
32 (0dB)
04
Transmit Gain Level for
Conference and Transfer Calls
Select the CODEC gain type
used by the trunk when it is part
of an Unsupervised Conference.
1~57
(-15.5dB ~ +12.5dB in 0.5dB intervals)
32 (0dB)
05
Receive Gain Level for
Conference and Transfer Calls
Select the CODEC gain type
used by the trunk when it is part
of an Unsupervised Conference.
1~57
(-15.5dB ~ +12.5dB in 0.5dB intervals)
16 (-8dB)

Table of Contents