SV9100 Programming Manual 2-231
Description
Use Program 15-22 : Mobile Extension Setup to set the system information for the Mobile Extension
feature.
Program 15 : Extension, Basic Setup
15-22 : Mobile Extension Setup
Level:
IN
Input Data
Extension Number 001 ~ 960
Item
No.
Item Input Data Default
01
Mobile Extension Target Setup
Set which Speed Dial bin is used
to call when the Mobile extension
is called.
0~9999 (0 = No setting/1~9999 = target of mobile extension)
0
02
Connect Confirmation
Select when a confirmation (dial )
is required to allow the call to cut
over to the called mobile number.
0 = Always
1 = On Analog Line
2 = Never
0
03
Trunk Access Code
Select if the Normal or Individual
Trunk access is used when
making the call to the mobile
number.
0 = Use normal trunk access code (11-09-01)
1 = Use individual trunk access code (11-09-02)
0
04
Call Back
Set up the Call Back for each
Mobile extension number.
0 = Disable
1 = Enable
0