Issue 4.0
2-42 Program 10 : System Configuration Setup
Description
Use Program 10-23 : SIP System Interconnection Setup to determine if the system is interconnected
and define the IP address of another system, call control port number and alias address for SV9100
system interconnection.
Conditions
None
Program 10 : System Configuration Setup
10-23 : SIP System Interconnection Setup
Level:
IN
Input Data
System Number
001~1000
Item No. Item Input Data Default
01
System
Interconnection
0 = No (Disable)
1 = Yes (Enable)
0
02
IP Address
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
03
Call Control Port
1~65535
1720
04
Dial Number
Up to 12 digits (0~9)
None
05
Keep Alive Mode
for SIP
0 = Disable
1 = Enable
0
06
SIP Profile
1 = Profile 1
2 = Profile 2
3 = Profile 3
4 = Profile 4
5 = Profile 5
6 = Profile 6
With Version 2000 or lower CPU
Software only two SIP Profiles are
supported.
1

Table of Contents